Ordering Recommendation

Aids in the diagnosis of C1q deficiency. For testing to detect circulating immune complexes, refer to Circulating Immune Complex, C1q Binding (0050301).

New York DOH Approval Status

Testing is not New York state approved. Specimens from New York clients will be sent out to a New York state-approved laboratory.

Specimen Required

Patient Preparation
Collect

Lavender (EDTA) or pink (K2EDTA).

Specimen Preparation

Separate plasma from cells ASAP or within 2 hours of collection. Transfer 1 mL plasma to an ARUP standard transport tube and freeze immediately. (Min: 0.1 mL)

Storage/Transport Temperature

CRITICAL FROZEN. Separate specimens must be submitted when multiple tests are ordered.

Unacceptable Conditions

Grossly hemolyzed, hyperlipemic, or room temperature specimens. Serum or non-EDTA plasma.

Remarks
Stability

Ambient: Unacceptable; Refrigerated: 48 hours; Frozen: 1 month

Methodology

Quantitative Immunoturbidimetry

Performed

Tue, Fri

Reported

5-10 days

Reference Interval

Test Number
Components
Reference Interval
  Complement Component 1q Level 106.6-187.8 mg/L

Interpretive Data



Compliance Category

Note

For the C1q Binding assay, refer to ARUP test code 0050301. The C1q Binding assay detects circulating immune complexes. The Complement Component 1q Level assay quantifies the active fraction component, C1q, of the C1 complement protein complex.

Hotline History

N/A

CPT Codes

86160

Components

Component Test Code* Component Chart Name LOINC
0099130 Complement Component 1q Level 4478-4
* Component test codes cannot be used to order tests. The information provided here is not sufficient for interface builds; for a complete test mix, please click the sidebar link to access the Interface Map.

Aliases

  • C1q Level
  • C1
  • C1q
  • Complement Component C1q
Complement Component 1Q Quantitative