Allergen, Food, Alpha-Gal (galactose-alpha-1,3-galatose) IgE
Ordering Recommendation
New York DOH Approval Status
Specimen Required
Multiple patient encounters should be avoided
Serum separator tube.
Separate serum from cells ASAP or within 2 hours of collection. Transfer 0.5 mL serum to an ARUP Standard Transport Tube. (Min: 0.25 mL). For multiple allergen orders refer to "Allergen Specimen Collection Instructions" at www.aruplab.com/testing/resources/specimen.
Refrigerated.
Hemolyzed, icteric, or lipemic specimens.
After separation from cells: Ambient: 48 hours; Refrigerated: 2 weeks; Frozen: 1 year
Methodology
Quantitative ImmunoCAP Fluorescent Enzyme Immunoassay
Performed
Sun-Sat
Reported
1-3 days
Reference Interval
Reporting Range (reported in kU/L |
Probability of IgE Mediated Clinical Reaction |
Class Scoring |
---|---|---|
Less than 0.10 | No significant level detected | 0 |
0.10-0.34 | Clinical relevance undetermined | 0/1 |
0.35-0.70 | Low | 1 |
0.71-3.50 | Moderate | 2 |
3.51-17.50 | High | 3 |
17.51-50.00 | Very high | 4 |
50.01-100.00 | Very high | 5 |
Greater than 100.00 | Very high | 6 |
Interpretive Data
Allergen results of 0.10-0.34 kU/L are intended for specialist use as the clinical relevance is undetermined. Even though increasing ranges are reflective of increasing concentrations of allergen-specific IgE, these concentrations may not correlate with the degree of clinical response or skin testing results when challenged with a specific allergen. The correlation of allergy laboratory results with clinical history and in vivo reactivity to specific allergens is essential. A negative test may not rule out clinical allergy or even anaphylaxis.
FDA
Note
Hotline History
Hotline History
CPT Codes
86008
Components
Component Test Code* | Component Chart Name | LOINC |
---|---|---|
3003925 | Allergen, Food, Alpha-Gal, IgE | 73837-7 |