Ordering Recommendation
Mnemonic
RESPAT RNA
Methodology

Massively Parallel Sequencing

Performed

Varies

Reported

3-6 days

New York DOH Approval Status
Specimens from New York clients will be sent out to a New York DOH approved laboratory, if possible.
Specimen Required
Patient Preparation
Collect

Bronchoalveolar lavage (BAL), sputum, tracheal aspirate, or nasopharyngeal swab.

Specimen Preparation

Transfer 2 mL BAL, sputum, or tracheal aspirate to an ARUP Standard Transport Tube. (Min: 1 mL) Place nasopharyngeal swab in viral transport media (ARUP Supply #12884) available online through eSupply using ARUP Connect™ or contact ARUP Client Services at (800) 522-2787. Place each specimen in an individually sealed bag.

Test is not performed at ARUP; separate specimens must be submitted when multiple tests are ordered.

Storage/Transport Temperature

Frozen

Unacceptable Conditions

Thawed specimens. Nasopharyngeal swab not in viral transport media.

Remarks

Specimen source required.

Stability

Ambient: Unacceptable; Refrigerated: 4 days; Frozen: 1 month

Reference Interval

By report

Interpretive Data



Compliance Category

Performed by non-ARUP Laboratory

Note
Hotline History
N/A
CPT Codes

87999

Components
Component Test Code* Component Chart Name LOINC
3002972 EER Respiratory Pathogens Detection, RNA 81655-3
3002973 Respiratory Pathogens RNA Detect, Source 31208-2
3002974 Respiratory Pathogens RNA Detection, NGS 50398-7
* Component test codes cannot be used to order tests. The information provided here is not sufficient for interface builds; for a complete test mix, please click the sidebar link to access the Interface Map.
Aliases
Explify Respiratory RNA Pathogen Detection