Ordering RecommendationRecommendations when to order or not order the test. May include related or preferred tests.
Investigate primary and secondary aldosteronism.
MnemonicUnique test identifier.
ALDO IVC
MethodologyProcess(es) used to perform the test.
Quantitative Chemiluminescent Immunoassay
PerformedDays of the week the test is performed.
Sun-Sat
ReportedExpected turnaround time for a result, beginning when ARUP has received the specimen.
Within 24 hours
New York DOH Approval StatusIndicates test has been approved by the New York State Department of Health.
This test is New York DOH approved.
Specimen Required
Patient Preparation
Collect
Adrenal venous sampling procedure is required. Serum Separator Tube (SST) or Plain Red.
Specimen Preparation
Separate from cells ASAP or within 2 hours of collection. Transfer 1 mL serum to an ARUP Standard Transport Tube. (Min: 0.5 mL)
Storage/Transport Temperature
Frozen.
Unacceptable Conditions
EDTA plasma.
Remarks
Stability
After separation from cells: Ambient: 8 hours; Refrigerated: 5 days; Frozen: 1 month
Reference IntervalNormal range/expected value(s) for a specific disease state. May also include abnormal ranges.
Interpretive DataBackground information for test. May include disease information, patient result explanation, recommendations, details of testing, associated diseases, explanation of possible patient results.
Compliance Category
FDA
NoteAdditional information related to the test.
Refer to the Additional Technical Information link for more information on Endocrine Society recommendations regarding patient preparation, specimen collection, medications for hypertension control during confirmatory testing for primary aldosteronism, and factors that may lead to false-positive or false-negative aldosterone-renin ratio (ARR) results.
Hotline History
N/A
CPT CodesThe American Medical Association Current Procedural Terminology (CPT) codes published in ARUP's Laboratory Test Directory are provided for informational purposes only. The codes reflect our interpretation of CPT coding requirements based upon AMA guidelines published annually. CPT codes are provided only as guidance to assist clients with billing. ARUP strongly recommends that clients confirm CPT codes with their Medicare administrative contractor, as requirements may differ. CPT coding is the sole responsibility of the billing party. ARUP Laboratories assumes no responsibility for billing errors due to reliance on the CPT codes published.
* Component test codes cannot be used to order tests. The information provided here is not sufficient for interface builds; for a complete test mix, please click the sidebar link to access the Interface Map.
AliasesOther names that describe the test. Synonyms.