Search our extensive Laboratory Test Directory to find test codes, ordering recommendations, specimen stability information, Test Fact Sheets, and more.
Recommendations when to order or not order the test. May include related or preferred tests.
In most cases, serology testing is not recommended for the diagnosis of active pertussis infection. CDC-recommended first-line tests for pertussis are Bordetella pertussis/parapertussis by PCR (0065080) and/or Bordetella pertussis Culture (0060117).
New York DOH Approval Status
Indicates whether a test has been approved by the New York State Department of Health.
Testing is not New York state approved. Specimens from New York clients will be sent out to a New York state-approved laboratory.
Specimen Required
Patient PreparationInstructions patient must follow before/during specimen collection.
CollectSpecimen type to collect. May include collection media, tubes, kits, etc.
Serum separator tube.
Specimen PreparationInstructions for specimen prep before/after collection and prior to transport.
Separate serum from cells ASAP or within 2 hours of collection. Transfer 1 mL serum to an ARUP Standard Transport Tube. (Min: 0.15 mL) Parallel testing is preferred and convalescent specimens must be received within 30 days from receipt of the acute specimens. Mark specimens plainly as "acute" or "convalescent." New York State Clients: 0.5 mL (Min: 0.25 mL)
Storage/Transport TemperaturePreferred temperatures for storage prior to and during shipping to ARUP. See Stability for additional info.
Refrigerated.
Unacceptable ConditionsCommon conditions under which a specimen will be rejected.
Bacterially contaminated, heat-inactivated, hemolyzed, icteric, lipemic, or turbid specimens.
RemarksAdditional specimen collection, transport, or test submission information.
StabilityAcceptable times/temperatures for specimens. Times include storage and transport time to ARUP.
After separation from cells: Ambient: 48 hours; Refrigerated: 2 weeks; Frozen: 1 year (avoid repeated freeze/thaw cycles) New York State Clients: Ambient: 1 week; Refrigerated: 2 weeks; Frozen: 1 month
Expected turnaround time for a result, beginning when ARUP has received the specimen.
1-5 days
Reference Interval
Normal range/expected value(s) for a specific disease state. May also include abnormal ranges.
Effective February 20, 2018
0.94 IV or less
Negative - No significant level of detectable B. pertussis IgG antibody.
0.95-1.04 IV
Equivocal Repeat testing in 10-14 days may be helpful.
1.05 IV or greater
Positive IgG antibody to B. pertussis detected, which may indicate a current or recent exposure/immunization to B. pertussis.
Interpretive Data
May include disease information, patient result explanation, recommendations, or details of testing.
This test was developed and its performance characteristics determined by ARUP Laboratories. It has not been cleared or approved by the US Food and Drug Administration. This test was performed in a CLIA certified laboratory and is intended for clinical purposes.
Compliance Category
Laboratory Developed Test (LDT)
Note
Additional information related to the test.
Hotline History
N/A
CPT Codes
The American Medical Association Current Procedural Terminology (CPT) codes published in ARUP's Laboratory Test Directory are provided for informational purposes only. The codes reflect our interpretation of CPT coding requirements based upon AMA guidelines published annually. CPT codes are provided only as guidance to assist clients with billing. ARUP strongly recommends that clients confirm CPT codes with their Medicare administrative contractor, as requirements may differ. CPT coding is the sole responsibility of the billing party. ARUP Laboratories assumes no responsibility for billing errors due to reliance on the CPT codes published.
* Component test codes cannot be used to order tests. The information provided here is not sufficient for interface builds; for a complete test mix, please click the sidebar link to access the Interface Map.