Ordering Recommendation

Use to assess fat malabsorption.

New York DOH Approval Status

This test is New York state approved.

Specimen Required

Patient Preparation

Fasting specimens preferred.

Collect

Serum Separator Tube (SST) or plain red.

Specimen Preparation

CRITICAL: Protect from light immediately after collection and during storage and shipment. Transfer 3 mL serum to ARUP Amber Transport Tube. (Min:0.6 mL)

Storage/Transport Temperature

Frozen. Separate specimens must be submitted when multiple tests are ordered.

Unacceptable Conditions

Any specimen other than serum. Refrigerated or room temperature specimens. Hemolyzed or icteric specimens.

Remarks
Stability

After separation from cells: Ambient: Unacceptable; Refrigerated: 4 hours; Frozen: 1 month

Methodology

Quantitative Spectrophotometry

Performed

Mon, Thu, Sat

Reported

1-4 days

Reference Interval

60-200 µg/dL

Interpretive Data



Compliance Category

Standard

Note

Hotline History

N/A

CPT Codes

82380

Components

Component Test Code* Component Chart Name LOINC
0080055 Carotene Total 2053-7
* Component test codes cannot be used to order tests. The information provided here is not sufficient for interface builds; for a complete test mix, please click the sidebar link to access the Interface Map.

Aliases

  • Carotene
Carotene, Serum Total