Ordering Recommendation
Mnemonic
VEG PRO
Methodology

Quantitative ImmunoCAP Fluorescent Enzyme Immunoassay

Performed

Sun-Sat

Reported

1-2 days

New York DOH Approval Status
This test is New York DOH approved.
Specimen Required
Patient Preparation

Multiple patient encounters should be avoided.

Collect

Serum separator tube. Multiple specimen tubes should be avoided.

Specimen Preparation

Separate serum from cells ASAP or within 2 hours of collection. Transfer 0.65 mL serum to an ARUP Standard Transport Tube. (Min: 0.4 mL)

Storage/Transport Temperature

Refrigerated.

Unacceptable Conditions

Hemolyzed, icteric, or lipemic specimens.

Remarks
Stability

After separation from cells: Ambient: 48 hours; Refrigerated: 2 weeks; Frozen: 1 year

Reference Interval

Allergens included: Carrot, Corn, Pea, Potato, Lima/White Bean.

Effective 02/18/2014

Reporting Range
(reported in kU/L)
Probability of IgE Mediated
Clinical Reaction
Class Scoring
Less than 0.10 No significant level detected 0
0.10 - 0.34 Clinical relevance undetermined 0/1
0.35 - 0.70 Low 1
0.71 - 3.50 Moderate 2
3.51 - 17.50 High 3
17.51 - 50.00 Very high 4
50.01 - 100.00 Very high 5
Greater than 100.00 Very high 6

Interpretive Data

Allergen results of 0.10-0.34 kU/L are intended for specialist use as the clinical relevance is undetermined. Even though increasing ranges are reflective of increasing concentrations of allergen-specific IgE, these concentrations may not correlate with the degree of clinical response or skin testing results when challenged with a specific allergen. The correlation of allergy laboratory results with clinical history and in vivo reactivity to specific allergens is essential. A negative test may not rule out clinical allergy or even anaphylaxis.

Compliance Statement A: For laboratory developed tests using a manufacturer labeled ASR as the reagent providing the specificity of the assay. Analyte Specific Reagent. This test was developed and its performance characteristics determined by ARUP Laboratories. The U. S. Food and Drug Administration has not approved or cleared this test; however, the FDA has determined that such clearance or approval is not necessary.

Note
Hotline History
N/A
CPT Codes

86003 x5

Components
Component Test Code* Component Chart Name LOINC
0055005 Allergen, Food, Carrot IgE 6061-6
0055041 Allergen, Interp, Immunocap Score IgE 33536-4
0055051 Allergen, Food, Potato IgE 6220-8
0055078 Allergen, Food, Corn IgE 6087-1
0099766 Allergen, Food, Lima Bean/White Bean IgE 7131-6
0099895 Allergen, Food, Pea IgE 6204-2
* Component test codes cannot be used to order tests. The information provided here is not sufficient for interface builds; for a complete test mix, please click the sidebar link to access the Interface Map.
Aliases
Allergens, Food, Vegetable Profile IgE